445 research outputs found

    Hysteresis of atmospheric parameters of 12 RR Lyrae stars based on multichannel simultaneous Stroemgren photometry

    Full text link
    RR Lyrae stars have been observed to improve the insight into the processes at work in their atmospheres. Simultaneous Stroemgren-photometry allows to obtain a rapid sequence of measurements in which photometric indices are unaffected by non-optimum observing conditions. The indices y, b-y, and c_1 are used with an established calibration to derive T_eff and to derive the gravity, log g_BJ from the Balmer jump, throughout the pulsation cycle. By employing the equations for stellar structure, additional parameters can be derived. Stroemgren photometry and its calibration in terms of T_eff and log g can be used to determine the run of R and the atmosphere pulsation velocity. We find that the Balmer-line strengths are correlated with T_eff and that the strength of the Ca_ii K line correlates well with the radius of the star and thus the pulsation-dependent density of the atmosphere. The density in the stellar atmosphere fluctuates as indicated by the changes in the gravity log g_BJ, derived from c_1, between 2.3 and 4.5 dex. Also the Stroemgren metal index, m_1, fluctuates. We find a disagreement between log g(T,L,M), the gravity calculated from T_eff, L, and the mass M,and the gravity log g_BJ. This can be used to reassess the mass and the absolute magnitude of an individual star.The curves derived for the pulsational velocity V_pul differ from curves obtained from spectra needed to apply the Baade-Wesselink method; we think these differences are due to phase dependent differences in the optical depth levels sampled in continuum photometry and in spectroscopy. We find an atmospheric oscillation in these fundamental mode RR Lyrae stars of periodicity P/7.Comment: 12 pages, 11 figure

    Be Stars: Rapidly Rotating Pulsators

    Full text link
    I will show that Be stars are, without exception, a class of rapidly rotating stars, which are in the majority of cases pulsating stars as well, while none of them does possess a large scale (i.e. with significant dipolar contribution) magnetic field.Comment: Review talk given at "XX Stellar Pulsation Conference Series: Impact of new instrumentation and new insights in stellar pulsations", Granada, 5-9 September 2011, in press in AIP Conf. Se

    A new approach to the assessment of lumen visibility of coronary artery stent at various heart rates using 64-slice MDCT

    Get PDF
    Coronary artery stent lumen visibility was assessed as a function of cardiac movement and temporal resolution with an automated objective method using an anthropomorphic moving heart phantom. Nine different coronary stents filled with contrast fluid and surrounded by fat were scanned using 64-slice multi-detector computed tomography (MDCT) at 50–100 beats/min with the moving heart phantom. Image quality was assessed by measuring in-stent CT attenuation and by a dedicated tool in the longitudinal and axial plane. Images were scored by CT attenuation and lumen visibility and compared with theoretical scoring to analyse the effect of multi-segment reconstruction (MSR). An average increase in CT attenuation of 144 ± 59 HU and average diminished lumen visibility of 29 ± 12% was observed at higher heart rates in both planes. A negative correlation between image quality and heart rate was non-significant for the majority of measurements (P > 0.06). No improvement of image quality was observed in using MSR. In conclusion, in-stent CT attenuation increases and lumen visibility decreases at increasing heart rate. Results obtained with the automated tool show similar behaviour compared with attenuation measurements. Cardiac movement during data acquisition causes approximately twice as much blurring compared with the influence of temporal resolution on image quality

    A Spectroscopic Orbit for Regulus

    Full text link
    We present a radial velocity study of the rapidly rotating B-star Regulus that indicates the star is a single-lined spectroscopic binary. The orbital period (40.11 d) and probable semimajor axis (0.35 AU) are large enough that the system is not interacting at present. However, the mass function suggests that the secondary has a low mass (M_2 > 0.30 M_sun), and we argue that the companion may be a white dwarf. Such a star would be the remnant of a former mass donor that was the source of the large spin angular momentum of Regulus itself.Comment: 18 pages, 2 figures, ApJL in pres

    Accelerating Feature Based Registration Using the Johnson-Lindenstrauss Lemma

    Full text link
    Abstract. We introduce an efficient search strategy to substantially accelerate feature based registration. Previous feature based registration algorithms often use truncated search strategies in order to achieve small computation times. Our new accelerated search strategy is based on the realization that the search for corresponding features can be dramat-ically accelerated by utilizing Johnson-Lindenstrauss dimension reduc-tion. Order of magnitude calculations for the search strategy we propose here indicate that the algorithm proposed is more than a million times faster than previously utilized naive search strategies, and this advan-tage in speed is directly translated into an advantage in accuracy as the fast speed enables more comparisons to be made in the same amount of time. We describe the accelerated scheme together with a full complex-ity analysis. The registration algorithm was applied to large transmission electron microscopy (TEM) images of neural ultrastructure. Our experi-ments demonstrate that our algorithm enables alignment of TEM images with increased accuracy and efficiency compared to previous algorithms.

    Quantification of biventricular myocardial function using cardiac magnetic resonance feature tracking, endocardial border delineation and echocardiographic speckle tracking in patients with repaired tetralogy of fallot and healthy controls

    Full text link
    Background: Parameters of myocardial deformation have been suggested to be superior to conventional measures of ventricular function in patients with tetralogy of Fallot (ToF), but have required non-routine, tagged cardiovascular magnetic resonance (CMR) techniques. We assessed biventricular myocardial function using CMR cine-based feature racking (FT) and compared it to speckle tracking echocardiography (STE) and to simple endocardial border delineation (EBD). In addition, the relation between parameters of myocardial deformation and clinical parameters was assessed. Methods: Overall, 28 consecutive adult patients with repaired ToF (age 40.4 ± 13.3 years) underwent standard steadystate- free precession sequence CMR, echocardiography, and cardiopulmonary exercise testing. In addition, 25 healthy subjects served as controls. Myocardial deformation was assessed by CMR based FT (TomTec Diogenes software), CMR based EBD (using custom written software) and STE (TomTec Cardiac Performance Analysis software). Results: Feature tracking was feasible in all subjects. A close agreement was found between measures of global left (LV) and right ventricular (RV) global strain. Interobserver agreement for FT and STE was similar for longitudinal LV global strain, but FT showed better inter-observer reproducibility than STE for circumferential or radial LV and longitudinal RV global strain. Reproducibility of regional strain on FT was, however, poor. The relative systolic length change of the endocardial border measured by EBD yielded similar results to FT global strain. Clinically, biventricular longitudinal strain on FT was reduced compared to controls (P<0.0001) and was related to the number of previous cardiac operations. In addition, FT derived RV strain was related to exercise capacity and VE/VCO2-slope. Conclusions: Although neither the inter-study reproducibility nor accuracy of FT software were investigated, and its interobserver reproducibility for regional strain calculation was poor, its calculations of global systolic strain showed similar or better inter-oberver reproducibility than those by STE, and could be applied across RV image regions inaccessible to echo. ‘Global strain’ calculated by EBD gave similar results to FT. Measurements made using FT related to exercise tolerance in ToF patients suggesting that the approach could have clinical relevance and deserves further study

    Automated diffeomorphic registration of anatomical structures with rigid parts: application to dynamic cervical MRI.

    No full text
    International audienceWe propose an iterative two-step method to compute a diffeomorphic non-rigid transformation between images of anatomical structures with rigid parts, without any user intervention or prior knowledge on the image intensities. First we compute spatially sparse, locally optimal rigid transformations between the two images using a new block matching strategy and an efficient numerical optimiser (BOBYQA). Then we derive a dense, regularised velocity field based on these local transformations using matrix logarithms and M-smoothing. These two steps are iterated until convergence and the final diffeomorphic transformation is defined as the exponential of the accumulated velocity field. We show our algorithm to outperform the state-of-the-art log-domain diffeomorphic demons method on dynamic cervical MRI data

    Определение трещиностойкости малоразмерных образцов технического титана ВТ1-0

    Get PDF
    Целью работы является ознакомление с новой методикой определения трещиностойкости конструкционных материалов, разрабатываемой в лаборатории физической мезомеханики ИФПМ СО РАН, и проверка методики на примере технического титана ВТ1-0. Испытания проводятся методом расклинивания малоразмерных образцов с шевронным надрезом. По полученным данным строится диаграмма нагружения в координатах "сила давления на клин – смещение сторон надреза". В качестве основной характеристики трещиностойкости определяется удельная энергия разрушения.The aim of this work is to study a new technique for determining the fracture toughness of structural materials and testing the technique using the samples of technical titanium VT1-0. The technique is developed in the laboratory of physical mesomechanics of ISPMS SB RAS. Tests are carried out by the method of wedging small-sized samples with a chevron notch. According to the obtained data, a loading diagram is constructed in the coordinates "force of pressure on the wedge - displacement of the sides of the incision". The specific fracture energy is determined as the main characteristic of crack resistance

    Computational Physics on Graphics Processing Units

    Full text link
    The use of graphics processing units for scientific computations is an emerging strategy that can significantly speed up various different algorithms. In this review, we discuss advances made in the field of computational physics, focusing on classical molecular dynamics, and on quantum simulations for electronic structure calculations using the density functional theory, wave function techniques, and quantum field theory.Comment: Proceedings of the 11th International Conference, PARA 2012, Helsinki, Finland, June 10-13, 201
    corecore